Hybrid temporary power solutions: how they work and the benefits for your site
Reliable power is essential to keeping projects moving. But when demand changes throughout the day, there may be opportunities to supply that power more efficiently.
Hybrid temporary power solutions combine generators, battery storage and, where suitable, renewable generation to match the way a site uses energy. By bringing these technologies together, businesses can reduce unnecessary generator runtime, lower fuel consumption and cut associated emissions while maintaining the power their operations need.
At Wernick Power Solutions, we design and manage temporary power solutions around each project’s requirements, helping customers identify where a hybrid approach can deliver practical benefits.
What is hybrid temporary power?
Hybrid temporary power uses a combination of power generation and energy storage technologies within one coordinated system.
A typical setup pairs a generator with a battery storage unit. Renewable technologies, such as solar panels (SolarFrame), can also contribute energy where site conditions and the system design allow.
Each component has a role. The generator supplies power and charges the battery when required. The battery stores electricity for use later, allowing suitable loads to be supported while the generator is switched off. Renewable generation can further reduce the energy required from the generator.
The right combination depends on how much power a site needs, when it needs it and the conditions in which the equipment will operate.
How does a hybrid temporary power system work?
Consider a site compound with busy daytime operations and a much smaller overnight load. During working hours, offices, welfare facilities and equipment may all need power. Overnight, demand may fall to lighting, security systems and other essential services.
With a suitably configured hybrid system, the generator can supply daytime demand and charge the battery. During quieter periods, stored energy can power the remaining loads without the generator running continuously. The generator restarts when charging or site demand requires it.
Wernick Power Solutions’ VoltBank battery storage units can work with compatible generators as part of this setup. Rather than choosing equipment around peak demand alone, our team considers the site’s wider pattern of energy use.
What are the benefits of hybrid temporary power solutions?
Lower fuel consumption and running costs
Using stored electricity during lower-demand periods can reduce generator operating hours and the fuel needed to support a site. The financial benefit depends on the load profile, equipment configuration and hire duration, so assessing the complete system is essential.
Reduced emissions
Reducing diesel use can lower the emissions associated with temporary power generation. Adding suitable renewable generation offers another opportunity to reduce reliance on generator-produced electricity.
Quieter periods of operation
Battery power allows periods of operation with the generator switched off. This can be particularly useful for overnight loads and sites near homes, offices or other noise-sensitive locations.
Flexibility as requirements change
Power demand can change as a project progresses. Reviewing the system against actual usage helps identify when equipment sizing, settings or the balance of generation and storage should be adjusted.
Where can hybrid temporary power be used?
Hybrid systems can support all sectors, including construction compounds, infrastructure projects, utilities works, events and industrial applications. They are particularly worth assessing where demand varies significantly between busy and quiet periods.
For example, a compound with overnight security loads may benefit from battery operation outside working hours. A site with suitable space and exposure may also be able to incorporate renewable generation.
Our SolarFrame and SolarFrame Plus products offer options for introducing solar, or combined solar and wind generation, into a suitable temporary power setup. Renewable output depends on weather and location, so the full system must still be designed to meet demand when generation is low.
Hybrid power in practice: Frog Lane compound
For South Gloucestershire Council’s Frog Lane compound, Wernick Power Solutions supplied a hybrid package combining a 60kVA generator, a 45kWh VoltBank battery storage unit, SolarFrame and fuel management.
The site’s July 2026 sustainability performance report recorded:
- 4,629 litres of fuel saved
- 15,104kg of CO₂e emissions avoided
- £5,765 in estimated cost savings
These are results from a specific site and reporting period. They illustrate the potential of a coordinated hybrid system; outcomes on other projects will depend on their operating conditions.
Using data to improve hybrid power performance
Selecting the equipment is only part of delivering an effective power solution. Understanding how it performs on site helps identify further opportunities to improve efficiency.
Our Power Optimisation Centre brings together operational data from connected generators, battery systems and renewable technologies. Our specialists review load profiles, generator runtime, battery activity and fuel consumption to identify where changes could improve performance.
This gives customers greater visibility of their temporary power use and supports decisions based on actual site demand.
Find the right hybrid temporary power solution for your project
Every site has different priorities, from keeping essential operations running to managing fuel costs, noise and emissions. Wernick Power Solutions assesses those requirements to recommend an appropriate combination of equipment, monitoring and support.
Whether you are planning a new project or reviewing an existing setup, our team can help you explore how hybrid temporary power could work for your site.
Contact Wernick Power Solutions to discuss hybrid temporary power solutions tailored to your next project.